Protego BR

DA-UB

In-Line Detonation Flame Arrester for unstable and stable detonations and deflagrations in a straight through design with a shock tube, bidirectional

Features

Optimized Performance
Due to the Patented Shock Wave Guide Tube Effect (SWGTE)
Use of Patented Shock Wave Guide Tube Effect (SWGTE)
Low Number of FLAMEFILTER® Discs Due to the Patented Shock Wave Guide Tube Effect (SWGTE)
Modular Design
Allows Replacement and Cleaning of Single FLAMEFILTER®
Differnt Series
Allow Increase of FLAMEFILTER® Size for Given Flange Connection Resulting in Lower Pressure Drop Across the Device
Easy Maintenance
Without Disassembling of the FLAMEFILTER®
Extended Application Range
for Elevated Operating Temperatures and Pressures
Bi-Directional Flame Transmission
Proof Design
Temperature Sensors Possible
Use of Temperature Sensors for G 1½ and G 2 Is Possible
Spare Parts
Cost-Effective Spare Parts
Low Costs
Low Operating and Lifecycle Costs
Function and Description

In-Line Detonation Flame Arresters with Shock Guide Tube Effect

The Type PROTEGO® DA-UB In-Line Detonation Flame Arresters are the newest generation of Flame Arresters. Based on fluid dynamic and explosion-dynamic calculations, as well as decades of field tests, a line was developed that offers minimum pressure loss and maximum safety. The device uses the Shock Wave Guide Tube Effect (SWGTE) to separate the flame front and shock wave. The result is an in-line detonation Flame Arrester without a classic shock absorber, and the use of flame-extinguishing elements is minimized.

Main Component – PROTEGO® Flame Arrester Unit

The devices are symmetrical and offer bi-directional flame arresting for deflagrations and stable and unstable detonations. The arrester essentially consists of two housing parts with an integrated shock tube (1) and the PROTEGO® Flame Arrester Unit (2) in the center. The PROTEGO® Flame Arrester Unit is modular and consists of several FLAMEFILTER® discs (3) and spacers firmly held in a FLAMEFILTER® casing. The number of FLAMEFILTER® discs and their gap size depends on the arrester’s intended use.

For Explosion Groups IIA to IIB3

By specifying the operating conditions, such as the temperature, pressure, explosion group, and the composition of the fluid, the optimum detonation arrester can be selected from a series of approved devices. PROTEGO® DA-UB Flame Arresters are available for explosion groups IIA to IIB3 (NEC group D to C MESG ≥ 0.65 mm).

Many Individual Certifications

The standard design can be used at an operating temperature of up to +60°C / 140°F and an absolute operating pressure up to 1.1 bar / 15.9 psi. Devices with special approval for higher temperatures and pressures (see table 3) are available upon request. EU conformity according to the currently valid ATEX directive. Approvals according to other national/international regulations on request.
Product Data

Dimensions

To select nominal width/nominal size (NG/DN) - combination, please use the flow capacity charts on the following pages
Additional nominal width/nominal size (NG/DN) - combinations for improved flow capacity upon request

NG150 / 6"150 / 6"200 / 8"300 / 12"400 / 16"500 / 20"600 / 24"700 / 28"800 / 32"1400 / 56"
DN≤ 50 / 2"65, 80 / 2 ½“, 3≤100 / 4"≤150 / 6"≤ 200 / 8"≤ 250 / 10"≤ 300 / 12"≤ 350 / 14"≤ 400 / 16"≤ 600 / 24"
a285 / 11.22285 / 11.22340 / 13.39445 / 17.52565 / 22.24670 / 26.38780 / 30.71895 / 35.241015 / 39.961675 / 65.94
bIIA -P1,1700 / 27.56800 / 31.501000 / 39.371200 / 47.241400 / 55.122200 / 86.61
IIA -P1,2388 / 15.28388 / 15.28488 / 19.21626 / 24.65
IIB3-P1,1500 / 19.69638 / 25.12724 / 28.50824 / 32.441000 / 39.371200 / 47.241400 / 55.12
IIB3-P1,2388 / 15.28388 / 15.28
c500 / 19.69500 / 19.69520 / 20.47570 / 22.44620 / 24.41670 / 26.38720 / 28.35770 / 30.31820 / 32.281060 / 41.73

Dimensions in mm / inches

Selection of explosion group

MESGExpl. Gr. (IEC / CEN)Gas Group (NEC)
≥ 0,65 mmIIB3C

Special approvals upon request

Selection of max. operating pressure

Expl. Gr.DN50 / 2"80 / 3"100 / 4"150 / 6"200 / 8"250 / 10"300 / 12"350 / 14"400 / 16"600 / 24"
NG150 / 6''150 / 6''200 / 8''300 / 12''400 / 16''500 / 20''600 / 24''700 / 28''800 / 32''1400 / 56''
IIAPmax1,8 / 26.11,8 / 26.11,6 / 23.21,6 / 23.21,1 / 15.91,1 / 15.91,1b / 15.91,1 / 15.91,1 / 15.91,6 / 23.2
IIB3Pmax1,5 / 21.71,5 / 21.71,5 / 21.71,5 / 21.71,1 / 15.91,1 / 15.91,1 / 15.91,1 / 15.91,1 / 15.9

Pmax = maximum allowable operating pressure in bar / psi absolute, higher operating pressure upon request in-between size up to Pmax upon request

Specification of max. operating temperature

≤ 60°C / 140°FTmaximum allowable operating temperature in °C
-Designation

higher operating temperatures upon request

Material selection for housing

DesignABC
HousingSteelStainless SteelHastelloy
Heating jacket (DA-UB-(T)-H-...)SteelStainless SteelStainless Steel
GasketPTFEPTFEPTFE
Flame arrester unitAB, CD

The housing is also available in Steel with an ECTFE coating. Special materials upon request

Material combinations of flame arrester unit

Design ABCD
FLAMEFILTER® cageSteelStainless SteelStainless SteelHastelloy
FLAMEFILTER®*Stainless SteelStainless SteelHastelloyHastelloy
SpacerStainless SteelStainless SteelHastelloyHastelloy

*the FLAMEFILTER® are also available in the materials Tantalum, Inconel, Copper, etc. when the listed housing and cage materials are used.

Special materials upon request

Flange connection type

EN 1092-1; Form B1
ASME B16.5 CL 150 R.F.

other connections upon request

Flow Capacity Chart

The flow capacity charts have been determined with a calibrated and TÜV certified flow capacity test rig. Volume flow V in (m³/h) and CFH refer to the standard reference conditions of air ISO 6358 (20°C, 1bar). For conversion to other densities and temperatures refer to Sec. 1: “Technical Fundamentals”.